![Laguna Tools MCNC SS2 4X8 6 HP LIQUID COOLED Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/laguna-tools/mcnc-ss2-4x8-6-hp-liquid-cooled/mcnc-ss2-4x8-6-hp-liquid-cooled_manual_670081031.webp)
30
MANUAL/Screen 3
The top three fields are for setting the Home speeds; from left to right: X, Y
and Z.
1)
SPINDLE DELAY is the time the program waits for the spindle to come to
speed before cutting begins.
2)
X, Y SPEED LIMIT is the top speed the controller will rapid at when 100%
of feed rate is required.
3)
Z, A SPEED LIMIT is the top speed the controller will rapid at when 100%
of feed rate is required.
4)
The lower indicators are used to verify the individual home switches are
functioning correctly; you can flag the home switches with something
ferrous, and activation will show on the corresponding light on the screen.
5)
MAX SPINDLE SPEED allows the controller to scale any spindle RPM
speed.