7
INFORMATION AREA
Hold the A button pressed for about 2 seconds to access the information area.
The display will sequentially show some information and the list of the door errors that have occurred,
if any:
SERIAL
: Serial code of the automation electronic control
unit
PARTIAL
: Number of operations performed since the
latest maintenance.
TOTAL
: Number of operations performed since the
installation.
REL A:
Software release of microprocessor A
REL B
: Software release of microprocessor B
INTCODE
: Code for internal use
ER1
: Error event code (latest)
ER2
: Error event code
ER3
: Error event code
ER4
: Error event code
ER5
: Error event code (earliest)
Scroll the sequence using the A (down) or C (up) buttons.
Press the SET button to return to the main screen.
DIAGNOSTIC AREA
You can check the state of the door inputs in real time to look for any failures or malfunctions of the
sensors and accessories connected to the automatic door.
To this purpose, hold the C button for about 2 seconds.
The “INPUT CHECK” message will continuously scroll on the alphanumeric character line.
From now on the displayed icons shall no longer indicate the operating programs; each of them,
instead, shall identify an activated door program. Please refer to the table below for information about
the meaning of each icon.
Press the SET button to exit the input display and return to the main screen.
RAD EX (13)
ETERNA AUTOMATION
NEXT 75 AUTOMATION
RAD EX (1)
AUX2 (4)
AUX1 (5)
E.O.1 - E.O.1 (8-9)
OPEN (3)
AUX2 (17)
AUX1 (16)
E.O.1 - E.O.1 (8-9)
STOP/INTERLOCK
PRJ38 (14)
OPEN (18)
START (11) RX
B button
E.C.2 (6)
RAD IN (12)
E.O.1 - E.O.1 (8-9)
LOCK1 (15)
E.C.1 (5)
E.C.1 (7)
E.O.1 (6)
RAD IN (2)
E.C.2 (6)
RX PS1