background image

5

After completing all the electrical connections to the electronic control unit of the automation (ETERNA/

NEXT), power the automatic door.

When  installed  for  the  first  time,  the  selector  shall  automatically 

switch to the language selection menu. 

Scroll the available languages using the A (down) or C (up) buttons 

until you find the desired one. Now press the SET button to confirm 

and exit this menu.

The language shall be saved and you shall no longer have to select 

it again. Should you later wish to change the language, access 

menu 5 from the technical area and repeat the operation. 

Once the language has been chosen the selector will automatically 

start detecting the doors existing on the serial communication line 

(up to 2); the data will be stored in the processor. During this step the 

“WAIT” message will be displayed on the alphanumeric character 

line. Wait for this step to be completed before you touch any button.

Warning!

The detection operation shall be automatically performed every time the door is powered, 

and shall take a few seconds.

If the operation has been successfully completed the selector will display on the alphanumeric character 

line the saved operating program for the door, along with its text, in the desired language.

The following paragraph provides a list of the available programs (you can also customise their visibility 

- see the SELECTOR OPTION chapter).

Should the “ NO COMM” message be displayed instead of one of the operating programs, the selector 

has detected no connected door. In this case check the connection and retry.

DAY-TO-DAY USE

The T-NFC model allows to select 6 different program types for day-to-day use:

AUTO:

   The door opens and closes automatically both ways with all sensors activated

EXIT:

  

The door only opens and closes automatically in the exit direction: the sensor connected to 

the External Radar input is temporarily disabled.

ENTER:

   The door only opens and closes automatically in the entry direction: the sensor connected 

to the Internal Radar input is temporarily disabled.

Содержание T-NFC

Страница 1: ...USER INSTRUCTIONS T NFC En Rel 1 0 01 2019 CD0749EN TRANSLATION OF THE ORIGINAL INSTRUCTIONS T NFC En DIGITAL SELECTOR for automatic doors ETERNA and NEXT ...

Страница 2: ......

Страница 3: ...ON 4 DAY TO DAY USE 5 OPENING THE DOOR FROM T NFC 6 INFORMATION AREA 7 DIAGNOSTIC AREA 7 TECHNICAL AREA 9 1 SET UP 9 2 FUNCTION 11 3 SELECTOR OPTION 12 4 LANGUAGE 13 5 CONNECTION 13 6 PASSWORD 14 7 SERVICE 14 TABLE OF CONTENTS ...

Страница 4: ...r power supply and the battery are off Connect the cable to the connector located on the electronic board fastened to the plastic casing cover 2 then close the cover onto the previously installed plastic casing 3 1 2 3 C button used to type the passwords to enable the F2 special functions to access the input display and for other uses in the technical area See the specific chapters D button used t...

Страница 5: ... button Warning The detection operation shall be automatically performed every time the door is powered and shall take a few seconds If the operation has been successfully completed the selector will display on the alphanumeric character line the saved operating program for the door along with its text in the desired language The following paragraph provides a list of the available programs you ca...

Страница 6: ...and thus activate the selector the screen brightness shall increase now press SET again multiple times until selecting the desired operating program Warning If no button has been pressed for about 20 seconds the selector automatically switches to Screen Saver mode and decreases the display brightness In addition to the operating program at any time you can select a reduced opening function normall...

Страница 7: ...turn to the main screen DIAGNOSTIC AREA You can check the state of the door inputs in real time to look for any failures or malfunctions of the sensors and accessories connected to the automatic door To this purpose hold the C button for about 2 seconds The INPUT CHECK message will continuously scroll on the alphanumeric character line From now on the displayed icons shall no longer indicate the o...

Страница 8: ...word 1 is the only one which grants access to the user password area as a consequence it should only be known by the owner of the shop organisation where the door is installed The service password 2 instead is intended for employees or external workers who can use it to change the door operating programs but have no way to change or disable both passwords To change password 1 press the A button af...

Страница 9: ...It is important and essential that the installer change the standard password to better protect the automatic door settings Hold the SET button pressed for about 2 seconds to enter the technical area The display will prompt you to type the technical password Type the password if the code is correct the selector shall enter the technical area and select the first of the 7 menus To switch between th...

Страница 10: ...numeric character line Important The opening direction is self learned provided the leaf is closed when the setup is launched Remember to close the door before launching the setup Now press the A button to launch the Setup A beep shall signal that the setup has started The door shall run an opening cycle at reduced speed then it shall emit a continuous beep for a few seconds to signal that the set...

Страница 11: ...llowing text From this position which shall be referred to as ZERO Position repeatedly press the B button or hold it pressed to fast forward to select the functions from the first F01 to the last F80 to return to the first function repeatedly press or hold pressed the A button To change the selected function state press the B button to disable it OFF or the D button to enable it ON Some functions ...

Страница 12: ...u allows to customise the T NFC selector As mentioned in the DAY TO DAY USE paragraph it allows to select 6 different operating programs to enable a reduced opening during winter and to activate a set of special functions through the C button In a simple installation these choices are often unnecessary and could confuse the end user For this reason the undesired operating programs and the buttons ...

Страница 13: ... switch to the first available program whose state is ON accordingly the A and C F2 buttons shall have no effect if their state is set to OFF After setting the customisation options press the SET button to return to the main page of the technical area To exit the technical area and return to the main screen press SET again 4 LANGUAGE This menu allows to select the language for the operating progra...

Страница 14: ...enance allows to reset some door parameters The following is a list of the available parameters To switch between the different parameters repeatedly press the B button After selecting the parameter to be used press the A button to activate one of the actions described below ERROR RESET It erases the event memory of the door containing the error messages COUNTER RESET It resets the door partial co...

Страница 15: ......

Страница 16: ...ERTIFIED COMPANY QUALITY SYSTEM UNI EN ISO 9001 2000 Made in Italy by S p A Via Ilariuzzi 17 A S Pancrazio P se 43126 PARMA ITALIA Tel 39 05 21 67 52 Fax 39 05 21 67 52 22 infocom labelspa it www labelspa com ...

Отзывы: