14
6-PASSWORD
This menu allows you to change the technical password, provided you know the one currently in use.
Important!
The technical password is stored in the microprocessor controlling the automatic door; as a
consequence, it is independent of the selector in use. Once it has been stored, in order to
access the door with any type of programmer (T-NFC, ET-DSEL, LabelTools App), you will
have to know its encoding.
The first message to be displayed shall be:
Type the new password.
The next screen shall be:
“Type the new password again.”
If the 2 passwords match, after briefly displaying the “WAIT“ message the selector will switch to the
main page of the technical area.
To exit the technical area and return to the main screen, press SET again.
7-SERVICE
This menu, mainly used during maintenance, allows to reset some door parameters.
The following is a list of the available parameters.
To switch between the different parameters, repeatedly press the B button. After selecting the parameter
to be used, press the A button to activate one of the actions described below.
ERROR RESET
It erases the event memory of the door containing the error messages.
COUNTER RESET
It resets the door partial counter.
GENERAL RESET
It resets all the parameters to the default values; you shall then have to launch
a full door setup.
PLUG AND PLAY
This function allows, after setting at the factory all the door operating parameters
(Functions and Potentiometers), to install them by just pressing the button
located on the electronic control unit of the automation. The door shall only set
up the sliding stroke, then it shall be ready to use right away.
Press the SET button to return to the main page of the technical area.
To exit the technical area and return to the main screen, press SET again.