11 - REPLACING THE GROUP GASKET
A
. Round metal block
B
. Sprayer
C
. Jet
D
. Gasket
E
. Jet fixing screw
F
. Filter
G
. Filter-holder
If, during the delivery, the coffee drips out of the edges of the fil-
terholder (
G
), this may be caused by the obstruction of the filter-hol-
der delivery hole, in which case the hole needs to be cleaned; if the
problem persists or, if when fitting the filter-holder into the brewing
unit it significantly moves beyond the unit centre, the group gasket
needs to be replaced (
D
).
In order to replace it, unscrew the jet fixing screw (
E
), remove the
jet (
C
) and the sprayer (
B
), and then use a screwdriver as a lever to
remove the round metal block (
A
) and subsequently the gasket (
D
).
After having removed the gasket, clean the site properly before pla-
cing the new gasket. Reinstall the components by following the abo-
ve listed steps in reverse order.
INSTRUCTION FOR THE WATER MAIN CONNECTION
WATER MAIN KIT ASSEMBLY
1
- Remouve the silicon pipe from the pump.
Connect the water pipe to the pump inserting the connec
tion.
- Insert the water pipe in the hole under the base of the
machine.
2
- Take away the valve and insert the water pipe in the
“T” connection 6).
3
- Remouve the “Y” connection and the related silicone
pipes.
- Insert the longest silicone pipe in the by-pass and put it
in the tank for the waste water.
ELECTRIC CONNECTIONS
Disconnect the 3 poles connection of the tank microswitch from the
wiring.
Connect the 3 poles connector with a cable (cod. 396550) to the
wiring.
Make a parallel connection between the elctro valve and the pump
feeding.
A
B
C
D
E
F
G
1
3
2
Содержание Verobar V
Страница 1: ...Verobar V Verobar S Piccolobar...
Страница 5: ......
Страница 36: ...35...
Страница 37: ...36...
Страница 38: ...Cod 2850008 Rev 00 Dicembre 2009...