EN
105
Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
• The parameter filling WITH PUMP allows
the technician to select the activation
of the water pump during the automatic
filling cycle of the service boiler.
• Only under unusual circumstances
would the option of “WITHOUT PUMP”
be chosen.
• The electronics installed in this es
-
presso machine give priority to the brew
boiler for pressure. The activation of
the auto-fill cycle during the brewing
process can reduce the overall dispens
-
ing pressure in the brew boiler.
• During the auto-fill cycle, if a brew
cycle is chosen, the auto-fill cycle is de
-
layed until all brew cycles are complete.
• The maximum permitted value for the
temperature setting is 129°C.
• SAFETY TEST allows to bring the steam
boiler temperature to 140°C, thus
triggering the safety valve. Once the
Enter Password
******
Steam Boiler
Settings
Steam Boiler
Autofill Delay
2 start 2 stop
5
The first value indicates the time in seconds between the detection of the need to fill and the start of filling.
The second value indicates the time in seconds between filling and its actual end.
Press the T3 button
to enter the menu, move with the buttons T1
and T2
to set the desired
automatic filling time, press the T3 button
to confirm the value.
Fill During Brew
YES
6
Press the T3 button
to enter the menu, move using the buttons T1
and T2
to select
YES
or
NO
,
press the
T3 button
to confirm the option.
Autofill Timeout
10 min
7
Press the T3 button
to enter the menu, move with the buttons T1
and T2
to set the desired
time, press the
T3 button
to confirm the value.
Fill With Pump
WITH PUMP
8
Press the T3 button
to enter the menu, move between the parameters using the buttons T1
and T2
to select
WITH PUMP
or
WITHOUT PUMP
, press the
T3 button
to confirm the option.