EN
104
Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
Enter Password
******
Steam Boiler
Settings
Steam Boiler
• This parameter enables the technician
to set various parameters of the steam
boiler.
• The temperature of saturated water is
proportional to the pressure inside the
Steam Boiler. Therefore it is possible to
regulate the pressure of the steam boiler
by means of electronic temperature
control. Please use the following tables
as reference when setting the steam
boiler temperature.
Temperature
Pressure
247°F/119°C
1.0 bar
260°F/127°C
1.5 bar
264°F/129°C
2.0 bar
Enter Password
******
1
After accessing the “Technical” programming menu and entering the password, use the buttons
T1
and T2
until the following screen is displayed.
Steam Boiler
Settings
2
Press the T3 button
to enter the menu.
Steam Boiler
ENABLED
3
Press the T3 button
to enter the menu, move between the parameters using the buttons T1
and T2
to select
ENABLED
or
DISABLED
, press the
T3 button
to confirm the option.
Steam Temp.
123,7°C 123,5°C
4
Press the T3 button
to enter the menu, move with the buttons T1
and T2
to set the desired
temperature, press the T3 button
to confirm the value.
Содержание kb90 Series
Страница 143: ...EN 143...
Страница 144: ......