EN
110
Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
Enter Password
******
Steam Boiler
Settings
Steam Boiler
• The parameter “Level Sensit.” allows the
technician to select the probe sensitivity
for steam boiler filling according to water
hardness.
• The black connection cable corresponds
to the working level probe.
• The red connection cable corresponds to
the minimum level probe.
• The sensitivity default value is high.
Exit
Menu
Restart Machine
for Changes
5
To exit the menu move between the parameters using the buttons T1
and T2
until the exit menu is
displayed.
Press the T3 button
to exit the menu.
6
Turn the Main Switch to the 0 position.
94.4 00:00
95.5 95.1 SB
7
Now it is possible to turn on again the espresso machine; set the main switch to position 1 and press any button
to complete machine switch on.