Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
valve has triggered disable the function.
• Should the safety valve fail to trigger
within approximately one minute of the
temperature reaching 140°C, disable
the function and replace the valve.
• Only qualified technicians can perform
this operation.
• DRAIN STEAM BOILER allows the
service staff to renew or “regenerate”
the water contained inside the steam
boiler, discharging about one half of the
water contained in the boiler.
• This procedure is recommended in case
the machine should remain inactive for
more than 8 hours and in any case at
least on a weekly basis.
Enter Password
******
Steam Boiler
Settings
Steam Boiler
Level Sensitiv.
HIGH
9
Press the T3 button
to enter the menu, move between the parameters using the buttons T1
and T2
to select
HIGH
,
MEDIUM
or
LOW
, press the
T3 button
to confirm the option.
Steam Boiler
Safety Test
10
Press the T3 button
to enable the function.
SB 124.3/140.0°C
Enter to Exit
11
Press the T3 button
to exit the function.
Drain Steam
Boiler
Close Water Valve
Enter when Ready
12
Press the T3 button
to enable the function.
Manually close the mixing valve to allow the drain of the water contained in the steam boiler.