EN
82
Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
Press Enter
To Exit
Press b To Stop
20.0g
G1B1 Saved
20.0g
4
On each button you can set two doses, one for a short shot, one for a long shot.
To set the brewing time of a short shot, press and release the button immediately, press again to stop and store
the desired dose.
To set the brewing time of a long shot, press and hold the button for about 2 seconds, press and release the
button immediately to store the desired dose.
The two doses of each key can be set independently from one another.
If one of the two doses is not set or does not refer to the corresponding dose of the first group, it will work as
continuous dose.
Press Enter
To Exit
5
Press the T3 button
to return to the doses programming.
Group Dose
Exit
6
Press T1
or T2
to continue with the programming of the other parameters.
• This parameter allows the operator to
program the amount of coffee (brewing
amount) for each Selection Indicator.
• The brewing amount can be set in terms
of time (sec.), pulses, mass or brewratio.
• Once programmed, the Selection
Indicator remains lighted.
• It is possible to set the dose for both
a short and a long shot on the same
Selection Indicator.
• PULSE mode: control of doses in volume
• MASS mode: control of doses in mass
• BREW RATIO mode: ratio between the
coffee powder and the weight of the
drink
Program Dose
Enter Password
******
Program
Mass Dose
(only on ABR espresso machine models)