20
APPLIANCE ELECTRIC CONNECTION:
The electric connection must comply with the current legal standards and regulations.
Before making the connection, check that:
- The system electrical rating and the current outlets are adequate for the maximum power output of the appliance (see
the label applied to the bottom of the casing).
-
The outlet or the system is equipped with an efficient ground connection in accordance with the current legal standards
and regulations. The company will not be responsible for the non-compliance with these instructions.
When the connection to the power supply network is made using an outlet:
- If the power cord is supplied without a plug, apply a standard plug that is suitable for the load indicated on the label.
Connect the wires according to the diagram shown in FIG.16 and check that:
letter L (phase) = brown wire;
letter N (neutral) = blue wire;
ground symbol
= green-yellow wire;
- The power cord must be positioned so that an overtemperature of 75 K will not be reached at any point.
- Do not use reductions, adapters or splitters since they might cause false contacts and lead to dangerous overheating.
When the connection is made directly to the electric network:
-
Use a device that ensures disconnection from the mains in which the contacts are opened to a distance that
permits complete disconnection according to the conditions for over-voltage category III.
- Remember that the ground wire must not be interrupted by the circuit-breaker.
- As an alternative, the electric connection can also be protected by a high-sensitivity residual current circuit-breaker.
- It is highly recommended to attach the special green-yellow ground wire to an efficient ground system.
WARNING: If the power cord is replaced, the ground wire (yellow-green) connected to the terminal, should be
longer than the other wires by about 2 cm.
TABLE N°3 :
TYPES OF POWER CORDS
OVEN OPERATION
WORK SURFACE OPERATION
CROSS SECTION
ONLY GAS BURNERS
3 X 0.75 mm²
GAS OVEN / GAS GRILL
GAS B 1 HOT PLATE
3 X 1 mm²
GAS B 2 HOT PLATES
3 X 1 mm²
ONLY GAS BURNERS
3 X 1 mm²
GAS OVEN/
GAS B 1 HOT PLATE
3 X 1,5 mm²
ELECTRIC GRILL
GAS B 2 HOT PLATES
3 X 2,5 mm²
ONLY GAS BURNERS
3 X 1,5 mm²
ELECTRIC OVEN
GAS B 1 HOT PLATE
3 X 2,5 mm²
GAS B 2 HOT PLATES
3 X 2,5 mm²
ATTENTION: The appliance conforms with the regulations of directives 90/396EEC (Gas Directive) regarding gas
appliances for domestic use and the like, 93/68 and 73/23 (Low Voltage Directive) regarding electrical safety and
2004/108/CE, 93/68 and 89/336 (EMC Directive) regarding electromagnetic compatibility.
APPLIANCE MAINTENANCE
REPLACING PARTS
Before performing any maintenance operation, disconnect the appliance from the gas supply and electricity
network.
To replace parts such as knobs and burners, just remove them from the seats without disassembling any part of the
cooker.
To replace parts such as nozzle supports, valves and electric components follow the procedure described in the burner
adjustment paragraph. To replace the valve or the gas thermostat, it is also necessary to disassemble the two rear gas
train brackets, loosening the 4 screws (2 per bracket) that attach it to the rest of the cooker and, unscrew the nuts that
attach the front burner valves to the control support, after removing all the knobs. To replace the gas or electric
thermostat, also disassemble the rear cooker guard, loosening the relative screws, to be able to pull out and reposition
the thermostat bulb.
To replace the oven bulb, just unscrew the protection cap that projects out inside the oven. (Fig.17)
WARNING: Before replacing the bulb, disconnect the appliance from the electric power supply.
WARNING
: The power cord supplied with the appliance is connected to that appliance with an
X
type connection (in
compliance with standards EN 60335-1, EN 60335-2-6 and subsequent amendments) for which it can be installed without
the use of special tools, with the same type of cord as the one installed.
If the power cord becomes worn or damaged, replace it based on the information reported in table 3 .
To replace the power cable, lift the terminal board’s cover and replace the cable. To access the terminal board in cookers
with a 3x2.5mm² cable, the back panel on the rear of the appliance must be removed.
WARNING: If the power cord is replaced, the installer shall ensure that the ground cable is longer than the
phase cables and also shall comply with the warnings regarding the electric connection.
Greasing the valves:
If it becomes difficult to operate the valve, it should be greased immediately by following the instructions listed below:
1) Disassemble the valve body by loosening the two screws located on the body of the valve.(Fig.18)
Содержание MG
Страница 46: ...46 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12...
Страница 47: ...47 Fig 13 Fig 14 Fig 15 T Fig 16 Fig 17 Fig 18 Fig 19 Fig 20 Fig 21 Fig 22 Fig 23 Fig 24...
Страница 48: ...48 Fig 25 Fig 26 Fig 27 Fig 28 Fig 29 Fig 30 Fig 31 Fig 32 Fig 33 Fig 34 Fig 35 Fig 36 Fig 37...
Страница 49: ...49 Fig 38 Fig 39 Fig 40 Fig 41 Fig 42 Fig 43 Fig 44 Fig 45 Fig 46 Fig 47...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52 Cod 310226...