SERVICE BULLETIN
FA2100CVDR
BULLETIN NO. FA2100CVDR SB017 R1
AVIATION RECORDERS
100 Cattlemen Rd., Sarasota, FL 24232
Telephone: 941-371-0811 Facsimile: 941-377-5591
Page 8 of 11
23‐70‐07-017 R1
B.
FA2100 Software Upload Procedure
(1) Connect the J1A rear connector of the FA2100CVDR to the ROC/6 or
ROC/7 using the Recorder Interface (RI) Cable Assy, P/N 17TES0057.
(2) Connect either 115 Vac/400 Hz, or +28 Vdc to the pig
−
tail connections of
the Recorder Interface (RI) Cable Assy. (Do Not connect both power in-
put types at the same time).
(3) Connect the Computer Interface Communications Cable/2 (CICC/2),
P/N17TES0070 and 17TES0072, to the EPP port of the ROC/6 or ROC/7.
(4) Connect the FA2100 Software Upload Cable Assembly, P/N 17TES0058,
to the FA2100 Recorder front panel GSE connector and the opposite end
to the Computer Interface Communications Cable/2 (CICC/2) Interface
Cable P/N: 17TES0072.
(5) Apply power to the FA2100CVDR Recorder under test.
(6) Turn ON the power to the ROC.
(7) Shut down the Recorder Interface (RI) by right clicking on the RI Icon in
the Windows System Tray at the bottom right of the screen. Select “shut-
down.”
NOTE:
You can not use RI and CICC Loader at the same time.
(8) Note the FDP & SMP version and checksum values listed on the label of
the FA2100CVDR Software Distribution CD.
(9) Insert the FA2100CVDR Software Distribution CD into the ROC.
(10) From the Windows desktop double click on the CICC Loader Icon.
(11) When the CICC Loader window appears, refer to Figure 2, select the
Browse button at the Load Directory and set the source to “D:\.” (If it is
not already present).
(12) Select the software load type by choosing the Recorder part number listed
that matches the part number found on the recorder identification label.
(13) Left click the Load button.
The document reference is online, please check the correspondence between the online documentation and the printed version.