COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
FA2100CVR
Rev. 15 Page 114
Apr. 14/16
Testing & Fault Isolation
23–70–04
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
Figure 110. CVR Test, Power Consumption Entry
(p)
Verify that the DC LED on the front of the RIU is on.
(q)
Enter the current value in amps (typically .52) in window and click on OK.
Figure 111. CVR Test, Power Consumption Entry
(r)
Connect the recorder front cable and click on OK.
Figure 112. CVR Test, Instruction Message
(s)
Verify that the DC LED on the front of the RIU is on.
(t)
Observe the Fault History Log window appears. Select Print if you want to
save the fault history or Close to continue.
(u)
Click on Yes. The autotest will now proceed in completing the autotest
which will take approximately 30 minutes or less.
The document reference is online, please check the correspondence between the online documentation and the printed version.