SERVICE BULLETIN
FA2100CVDR
BULLETIN NO. FA2100CVDR SB017 R1
AVIATION RECORDERS
100 Cattlemen Rd., Sarasota, FL 24232
Telephone: 941-371-0811 Facsimile: 941-377-5591
Page 7 of 11
23‐70‐07-017 R1
III.
ACCOMPLISHMENT INSTRUCTIONS
CAUTION:
ELECTROSTATIC DISCHARGE (ESD) WARNING: Since the FA2100CVDR
contains electrostatic sensitive devices, it must be modified at a workstation
equipped for such devices. Before handling printed wiring assemblies, en-
sure that proper personal ESD grounding techniques are used.
A.
Installing CICC Loader and CICC Interface Utility Programs into the
ROC/6 or ROC/7.
The CICC Loader and CICC Interface utility executable programs are needed
to upload the recorder software and to verify that the upload process has been
achieved without any errors. To load these programs onto the ROC perform
the following steps:
(1) Turn ON the power to the ROC.
(2) Insert the CICC Loader CDROM into the ROC.
(3) At the Windows desktop, shut down the Recorder Interface (RI) by right
clicking on the RI Icon in the Windows System Tray at the bottom right of
the screen. Select “shutdown.”
(4) To install the CICC Loader from the Windows Start Menu, use the Browse
button to locate the setup.exe file on the CDROM and click the OK button.
(5) Follow the instructions on the Install Wizard and accept all defaults. The
Install Wizard will create a folder located at c:\Program Files\L-3
Com\CICC Loader. Left click and hold the CICC Loader (CICCLdr) icon
and drag it on to the desktop to create a short-cut.
(6) Insert the CICC Interface CDROM. Use the Browse button to locate the
setup.exe file on the CDROM and click the OK button.
(7) Follow the instructions on the Install Wizard and accept all defaults. The
Install Wizard will create a folder located at c:\Program Files\L-3
Com\CICC Interface. Left click and hold the CICC Interface (CICCIfc)
Icon and drag it on to the desktop to create a short-cut.
The document reference is online, please check the correspondence between the online documentation and the printed version.