COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
FA2100CVR
Rev. 15 Page 182
Apr. 14/16
Testing & Fault Isolation
23–70–04
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
(8)
Insert the FA2100 CD into the PC, RAU, or ROC/5
−
ROC/6
−
ROC
−
7 Ground
Station system CD.
(9)
From the Windows 98 or XP desktop, activate the (put in new PC & SW)
CICC Loader utility program by double
−
clicking on the CICCLdr Icon.
(10) When the CICC Loader window appears select the Browse button at the Load
Directory and set the source to “D:\.” (If it is not already present).
(11) Select the software load type by choosing the Recorder part number listed that
matches the part number found on the recorder identification label.
(12) Left click the Load button.
(13) Observe the progress window and verify that a status pop
−
up window appears
stating that the FA2100 loaded successfully. Note: if the load procedure was
unsuccessful, recycle power to the FA2100CVR and repeat steps (4)
−
(9).
NOTE:
If still unsuccessful, make sure that the address of the par-
allel port specified in the CICCLDR.ini file matches the ad-
dress of the parallel port connected to the CICC.
(14) Turn off power from the recorder and Exit the CICC Loader utility program.
(15) Disconnect the 17TES0058 Upload Cable from the FA2100CVR Front Panel
ATE connector and the 17TES0072 CICC/2 Cable Assembly.
(16) Reconnect the 17TES0072 CICC/2 Cable Assembly to the ATE connector.
(17) Proceed to paragraph C. to verify the software upload.
C.
To Verify the Software Upload
Once the FA2100 software has been loaded it needs to be verified using the CICC
Interface Software Utility as follows:
(1)
Apply power to the FA2100CVR Recorder.
(2)
From the Windows 98 or XP desktop, activate the CICC Interface utility pro-
gram by double
−
clicking on the CICCIfc Icon.
(3)
From the CICC Interface Menu, select the Version Command from the list and
left click the Send Command button. Observe that a pop-up window appears
showing the recorder software Part Number and SMP Checksum.
NOTE:
If the “FA2100 Command” window is disabled, make
sure that the address of the parallel port specified in
the CICCIFC.ini file is that same as the address of the
parallel port connected to the CICC.
The document reference is online, please check the correspondence between the online documentation and the printed version.