5.12.1
Malf / CB Status
This page is selectable from the
tab suite and displays the status of
malfunctions, circuit breakers, radio stations and other entities.
Descriptive text lines appear, chronologically, at the display, with a time stamp on their
incidence. When the number of incidents registered exceeds the page capacity, further
pages are generated and linked.
Those conditions which may be reset are provided with selection buttons.
The information and control provided by this page are as follows:
Active
Malfunctions
These are identified in red text. Selection of an associated button
displays a keypad, which allows the malfunction definition to be
displayed, or for it to be set inactive.
Armed
Malfunctions
These are identified in yellow text, each with its selected arming
conditions. Selection of an associated button displays a keypad,
which allows the malfunction definition to be displayed, for the
arming conditions to be changed, for the malfunction to be
activated, or for it to be disarmed.
Failed Stations
Failed radio stations are identified in cyan text. Selection of an
associated button displays a keypad, with options to view the
station information, to restore the station (or to fail or restore co-
located facilities), or to select it as the area map reference centre.
Circuit Breakers
These are circuit breakers which are within the simulated area and
have been thermally tripped, and are identified in magenta text.
Misc
These are typically simulation "freeze" conditions and are
identified in green text. Selection of an associated button resets
the condition.