2.4 During Operation
If the simulator or building fire alarm operates evacuate the flight compartment
immediately.
If you discover a fire, operate an emergency stop then evacuate the simulator.
There is a portable fire extinguisher in the flight compartment - fight the fire only if
you feel it is safe to do so - DO NOT put yourself or others in danger.
If the electrical or hydraulic power fails for an unknown cause and the simulator
does not settle, contact the maintenance team to determine the reason.
If the motion or control loading operates in an unsafe condition, operate an
emergency stop. Make sure that all persons remain seated with their seat belt
fastened until the flight compartment settles to the access position.
When the motion is disengaged make sure that all persons stay seated with their
seat belt fastened until the simulator settles to the access position.
In normal use the instructor seat should only be moved using the seat FWD and
BACK controls on the IOS control panel, make sure that the simulator is in the
parked or flight freeze position before moving. If the electrical power fails the
instructor seat can be moved manually after the seat is unlocked using the manual
override lever.
2.5 Instructor Station Post flight checklist
At the end of a training session, it is desirable to return the simulator to normal conditions.
To achieve this, follow the step outlined below.
-.
Pressing TOTAL RESET from the Freezes and Resets IOS page to perform a total
reset.