16
3.4 Timing Chart
①
Pressurize right after dressing the tip.
(
Recommended Pressure:1500N Maximum:3000N
)
②
When the PC is ON and the data strobe is OFF, turn ON the shoot command. (Keep the shoot command)
③
By receiving the command, the software takes a photo, process the photo, and send back the judgement
result back to the PLC.
④
The PLC processes the result and turn OFF the shoot command.
⑤
The judge software recieves the signal of the command turning OFF and turns OFF the result.
⑥
Release the pressure.
When OK judge was made
When NG judge was made
Dia. Judge NG
→Signal Dia. Judge is OFF
REM. Judge NG →Signal REM. Judge is OFF
The camera signal will turn ON/OFF at the same time as data strobe signal if the system is properly working.
Amount of time it takes from receiving the command to turning OFF the result output is approx. 1 sec.(But, it
may depends on the spec of PC and LAN)
When the shooting is done in plural cameras, the total time to process will be cumulative.
(EX: When using 3 cameras, total time will be about 3sec.)