![Kyocera Mita KM-4530 Скачать руководство пользователя страница 308](http://html1.mh-extra.com/html/kyocera-mita/km-4530/km-4530_service-manual_2017037308.webp)
2BC/D
2-1-26
(2-4) Toner control level absolute humidity correction
The results of toner density detection vary with the temperature and humidity due to their influence on the toner sensor
output characteristic. Therefore, the toner control level is corrected based on the absolute humidity level detected by the
humidity sensor PCB (HUMPCB).
3.5
3
0
0
1.4
3.1
11.4
22.7
35.8
Toner control level (V)
Absolute humidity (g/m
3
)
The above correction is for when “TARGET” of U154 is 154.
Figure 2-1-28
Toner control level absolute humidity correction