![Kyocera Mita KM-4530 Скачать руководство пользователя страница 304](http://html1.mh-extra.com/html/kyocera-mita/km-4530/km-4530_service-manual_2017037304.webp)
2BC/D
2-1-22
(1) Formation of magnetic brush
The developing magnet consists of a magnet roller with five poles and a sleeve roller. Rotation of the sleeve roller around
the magnet roller entrains developer, which in turn forms a magnetic brush at pole N1 on the magnet roller that is used
for developing. The height of the magnet brush is regulated by the doctor blade; the developing result is affected by the
position of the poles on the magnet roller and the position of the doctor blade. A developing bias voltage generated by
the high voltage transformer PCB (HVTPCB) is applied to the developing magnet to provide image contrast.
Developing magnet
Doctor blade
A
S2
N3
S1
N1
N2
43.5
59
85.5
74.5
Poles on the developing magnet
N1: 830
×
10
-4
N2: 630
×
10
-4
N3: 450
×
10
-4
S1: 860
×
10
-4
S2: 700
×
10
-4
A: 0.53
±
0.05mm (between the doctor blade and the developing magnet)
Figure 2-1-25
Forming a magnetic brush
Содержание KM-4530
Страница 1: ...SERVICE MANUAL Published in Apr 02 2BC70761 Revision 1 KM 4530 5530...
Страница 76: ...2BC D 1 1 4 13 This page is intentionally left blank...
Страница 100: ...1 4 35 2BC D 1 This page is intentionally left blank...
Страница 142: ...2BC D 1 This page is intentionally left blank...
Страница 173: ...2BC D 1 This page is intentionally left blank...
Страница 187: ...2BC D 1 1 5 42 This page is intentionally left blank...
Страница 355: ...2BC D 2 3 20 CN1 CN7 CN5 3 1 1 6 CN2 1 6 CN6 3 1 CN4 1 1 6 16 Figure 2 3 8 Scanner drive PCB silk screen diagram...
Страница 374: ...2BC D 1 2 4 16 This page is intentionally left blank...
Страница 380: ...2BC D 1 2 4 22 This page is intentionally left blank...