Service Manual

7

For internal use only

Option 5

3 induction zones with +/- keys on each zone (zone 1 is missing here),  2 digit timer with +/- 
keys, child-lock (led to indicate the lock state), IR port for configuration, buzzer 

Option 6

3 induction zones with +/- keys on each zone (zone 1 is missing here), no timer, child-lock 
(led to indicate the lock state), IR port for configuration, buzzer

6.

Communication and connectors

On the USIF there will be two WIDE connectors, for the communication between each IPC (Induction
Power Converter) and the USIF, a SAM connector (for service maintenance) and an Infrared port (IR). 

Содержание EKI 6130

Страница 1: ...Induction hobs EKI 6130 6140 G1 Series Configuration and failure codes...

Страница 2: ...Manual H1 53 01 Responsible Dieter Rutz K PPERSBUSCH HAUSGER TE AG Email dieter rutz kueppersbusch de Tel 0209 401 732 Customer Service Fax 0209 401 743 Postfach 100 132 Date 25 08 2010 45801 Gelsenk...

Страница 3: ...layouts 6 6 Communication and connectors 7 7 System failures 8 7 1 Failure types 8 8 Failure codes 10 9 Configuration and test mode 11 9 1 Access to the Test and configuration Mode 11 9 2 Main menu 1...

Страница 4: ...rly connected The ground wire resistance must not exceed that specified in the standard It is vital for ensuring the safety of persons and the functioning of the appliance On completion of repairs an...

Страница 5: ...stic electrical appliances The operating principle is innovating Contrary to other cooking modes it is the container itself which heats and not the hob You put a saucepan down and this is sufficient t...

Страница 6: ...f the detection recovery method At no greater than 10 seconds duration of the aforementioned power line disruption the disturbance will be considered a power failure A line disturbance meeting the cri...

Страница 7: ...figuration buzzer Option 6 3 induction zones with keys on each zone zone 1 is missing here no timer child lock led to indicate the lock state IR port for configuration buzzer 6 Communication and conne...

Страница 8: ...en a long beep is emitted Every failure type 1 that concerns one cooking zone only is only shown on the display of that cooking area Supposing to have the error coded with F21 on zone 1 then it will b...

Страница 9: ...ow the user to utilize the whole hob When this type of failure occurs the USIF switches OFF all the cooking zones present on the hob sending down power levels equal to zero and it becomes insensitive...

Страница 10: ...ultaneously touching and keys corresponding to that heater Code Type of failure Failure description Possible solution F12 1 IPC error low current in coil If persistent change IPC F21 External cause Ma...

Страница 11: ...g the FIRST connection to power supply In such situation USIF needs some seconds to calibrate its keys and strong lights might disturb this activity 9 1 Access to the Test and configuration Mode 1 UNP...

Страница 12: ...2 Main menu Once the right test sequence is introduced the USIF will enter the main menu providing the following options Configuration Checking To show these two letters the USIF will use the cooking...

Страница 13: ...onfiguration menu it is necessary to press the Child lock button when CO is shown on the displays Once this configuration sub menu CO is acceded 70 different hob configurations already stored in the E...

Страница 14: ...a failure EE will be displayed for 5 seconds on the displays instead of CO and a constant beep will be emitted Then the menu CO is possible to be entered again IMPORTANT After leaving Configuration M...

Страница 15: ...rtant remarks that shall be considered when changing some parts of the system Next picture shows a general view of the induction module together with the name given to each component 10 1 General view...

Страница 16: ...s to TC as shown in the next picture Connection of communication cables Each time a TC and or IPC s is are changed during service intervention it is compulsory to perform the configuration of the hob...

Страница 17: ...is to be connected Configuration SS has same size and kind of res caps small The small pair of res caps is intended to drive coils of diameter 145 180 or dual 260 A SS IPC has to be used when coils di...

Страница 18: ...identify address 2 the IPC placed in position B MUST include a jumper in connector J6P as shown in the figure on page 13 No jumper placed means address 1 so IPC placed in position A needs no jumper I...

Страница 19: ...d on the IPC board while the temperature sensor is connected in its connector near the towers Substitution of a dual coil is described in the following section 10 5 2 Substitution of a dual coil One I...

Страница 20: ...EKI 6140...

Страница 21: ......

Страница 22: ......

Страница 23: ...EKI 6130...

Страница 24: ......

Страница 25: ......