16
Service Manual
For internal use only
10.2
Substitution of the Touch Control
When changing a defective TC for a new one, it should be taken special care on the right connection of
the cables from IPCs to TC, as shown in the next picture.
Connection of communication cables
Each time a TC and/or IPC(s) is/are changed during service intervention, it is
compulsory to perform the configuration of the hob. Otherwise the system might not
work properly.
left TC connection
connected to IPC
generator in position A
(left),
direction 1
right TC connection
connected to IPC
generator in position B
(right),
direction 2