Error codes are a precious aid to diagnostic. Take care to well identify the model to be troubleshooted,
as codes do not always have the same meaning. In the following table there are gathered the codes and
detailed descriptions, showed in the USIF, of the failures that could happen in the appliance from the
IPC side.
The code to be shown on the display is reported with an ‘F’ before (or a ‘C’ for failure number > 80), this
is just to distinguish these two codes.
Note
:
On hobs with TC software version prior to 3.30, it may occasionally happen that the residual
heat indicator ‘H’ keeps fixed after the glass has cooled down. In such a situation like this,
the ‘H’ is removed by simultaneously touching “+” and “-” keys corresponding to that heater.
Code
Type of failure
Failure description
Possible solution
F12
1
IPC error (low current in coil)
If persistent, change IPC.
F21
External cause
Mains frequency wrong.
Verify mains frequency.
F25
2
Fan stuck on IPC #
Change fan.
F36
1
Coil # temperature sensor
shortcircuited. NTC value is
out of the specified range.
Change coil.
F37
1
Wrong connection or NTC
unconnected.
Review connection – Change coil.
F40
1 or 2
IPC error.
Change IPC.
F42
External cause
Mains over voltage.
Verify mains voltage.
F43
External cause
Mains low voltage.
Verify mains voltage.
F47
2 or 3
Communication between
USIF and all the IPCs is not
working.
Verify mains voltage.
F56
3
Wrong or invalid USIF
configuration.
Repeat configuration.
F58
2
Wrong or invalid USIF
configuration.
Repeat configuration.
F60
3
USIF error.
Change USIF.
C81
2
Board overheated.
Let it cool down.
C82
2
Coil overheated.
Let it cool down.