18
Service Manual
For internal use only
10.4.1 Position of IPCs inside the induction module
A standard induction module includes 2 IPCs that can be placed in 2 different positions or addresses.
Position
A
means address 1, and position
B
means address 2, as shown in figure “Configuration mode
(CO)” on page 12. When changing one IPC, it should be taken care that the correct address is assigned.
In order to identify address 2, the IPC placed in position “B” MUST include a jumper in connector J6P as
shown in the figure on page 13. No jumper placed means address 1, so IPC placed in position “A” needs
no jumper.
IPC in position “A” needs NO jumper.
IPC in position “B” needs jumper.Otherwise the system will not be configured properly!
Connector J6P
Each time a TC and/or IPC(s) is/are changed during service intervention, it is
compulsory to configure the hob. Otherwise the system might not work properly.
jumper
connected in
J6P for an IPC
in position “B”
(adress 2)
jumper connected in J6P for IPC in position “B” (adress 2)