IC-Module for EtherNet/IP
86 / 137
0x4009 Firmware Version
In this memory register you will find information for the firmware
version.
Modbus Register
0x4009
Value Range
0x0000 - 0xffff
Default Value
-
Number of bytes avail-
able
2
Permanently stored
Constant
Access
Read Only
0x400a-0x400b Serial
Number
In these memory registers have the option, to change the serial
number of the IC-Modul
e
.
In the delivered condition the KUNBUS serial number is stored.
The Memory Register 0x400a contains the High Word, register
0x400b contains the Low Word of the serial number.
Modbus Register
0x400a-0x400b
Value Range
0x00000000 - 0xffffffff
Default Value
KUNBUS Serial number
Number of bytes avail-
able
4
Permanently stored
Yes
Access
Read/Write
0x400e Configure IP Address
via SSC
Prerequisite:
You have connected the address switch.
This Memory Register contains the value of the first two input byes
from the SSC channel. You can use these bytes as part of the
Device address if you make the appropriate settings in register
0x4012.
Tip!:
In Appendix 2 you will find an example for the connection of an
address switch.
You can determine the number of bytes in the register 0x0025.
Modbus Register
0x400e
Value Range
0x0000 – 0xffff
Default Value
-
Number of bytes available
2
Permanently stored
No
Access
Read Only
Memory Register