IC-Module for EtherNet/IP
38 / 137
Error Codes
Error code
Designation
Description
0x01
INVALID_DATA_
ADDRESS
Invalid data address
The master tries to access an invalid ad-
dress.
The slave ignores the instruction.
0x02
INVALID_DATA_
LENGTH
Invalid data length
The data length predefined by the master is
too great.
The slave ignores the instruction.
0x04
INVALID_DATA
Invalid data
The master tries to write data containing
values outside a valid range.
The slave ignores the instruction.
0x08
INVALID_ACCESS
Invalid access
The master tries to access an invalid area
or a valid address.
The slave ignores the instruction.
0x10
INVALID_RANGE
Invalid range
The master tries to write beyond the limits
of an SSC input data area or to write bey-
ond the limits of an SSC, SDI or FBS output
data area.
The slave ignores the instruction.
0x20
UNDEFINED_ERROR
Undefined error
An undefined error has occurred.
The slave ignores the instruction.
Table 1:
Error Codes
Components