![KTR-Group ROTEX 001 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/ktr-group/rotex-001/rotex-001_operating-and-assembly-instructions_2008253018.webp)
ROTEX
®
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
40210 EN
18 of 22
22
Please observe protection
note ISO 16016.
Drawn:
2017-09-06 Pz/Bru
Replacing:
KTR-N dated 2017-01-02
Verified:
2017-09-06 Pz
Replaced by:
Type
Hub design
Sizes
Material
001
Standard
1.0, 1.1, 1.3
1a (large hub)
clamping set 4.1, 4.2, 4.3
38 - 90
Cast iron (GJL)
100 - 180
Nodular iron (GJS)
14 - 180
Steel
Clamping sleeve
Taper clamping sleeve
24 - 125
019
Clamping ring hub
6.0, 6.5
19 - 90
Clamping hub
2.0, 2.1, 2.3
19 - 180
018
DKM
1.0, 1.1
spacers for drop-out center lengths 10
to 40 mm
19 - 90
ROTEX
®
DKM and ROTEX
®
ZS-DKM only with spacer made of steel or aluminium semi-finished products with a
yield point of R
p0.2
≥ 250 N/mm
2
.
Hubs, clamping hubs or similar types without feather keyways may be used in category 3
only.
Conditions of operation in
hazardous locations
ROTEX
®
couplings are suitable for the use according to EU directive 2014/34/EU.
1. Industry (with the exception of mining)
Equipment group II of category 2 and 3 (
coupling is not approved for equipment group 1
)
Media class G (
gases, fogs, steams
), zone 1 and 2 (
coupling is not approved for zone 0
)
Media class D (
dusts
), zone 21 and 22 (
coupling is not approved for zone 20
)
Explosion group IIC (
explosion class IIA and IIB are included in IIC
)
Temperature class:
T-PUR
®
PUR
Temperature class
Ambient or
operating
temperature T
a
Max. surface
temperature
Temperature class
Ambient or
operating
temperature T
a
Max. surface
temperature
T3, T2, T1
- 50 °C to
+ 120 °C
1)
+ 140 °C
2)
T4, T3, T2, T1
- 30 °C to
+ 90 °C
1)
+ 110 °C
2)
T4
- 50 °C to + 115 °C
+ 135 °C
T5
- 30 °C to + 80 °C
+ 100 °C
T5
- 50 °C to + 80 °C
+ 100 °C
T6
- 30 °C to + 65 °C
+ 85 °C
T6
- 50 °C to + 65 °C
+ 85 °C
Explanation:
The maximum surface temperatures each result from the maximum permissible ambient or operating temperature T
a
plus the maximum
temperature increase
T of 20 K which has to be taken into account.
1) The ambient or operating temperature T
a
is limited to + 90 °C (valid for T-PUR
®
only: + 120 °C) due to the permissible permanent
operating temperature of the elastomers used.
2) The maximum surface temperature of + 110 °C (valid for T-PUR
®
only: + 140 °C) applies for the use in locations which are potentially
subject to dust explosion, too.
10
Enclosure A
Advice and instructions regarding the use in
hazardous locations
10.1 Intended use in
hazardous locations