KTR-STOP
®
M-xxx B-xx-xx
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
445102 EN
22 of 22
3
Please observe protection
note ISO 16016.
Drawn:
2020-03-25 Shg/Wie
Replacing:
KTR-N dated 2019-08-26
Verified:
2020-03-25 Shg
Replaced by:
Technical data:
Operating temperature
- 40 °C to + 85 °C
Max. voltage
30 V DC/AC
Switching current
100 mA
Protection class
IP 65 (mounted)
Width across flats
24 mm
Max. tightening torque G 1/2
20 Nm
Max. tightening torque M12
hand-tight
Length of cable
5 m, 10 m or 15 m
Material of cable
PUR
Dimension of cable
5 * 0,34 mm
2
Illustration 19: Pin assignment of plug-in connection
•
Remove the screw plug (component 1.20) from the
setting nut (component 1.7).
•
Hand-tighten the sensor (component 4) into the settting
nut first (see illustration 20).
•
Tighten the sensor at the tightening torque
T
A
= 20 Nm.
•
Provide for the electric connection according to the
plug-in connection (see illustration 19).
Illustration 20: Assembly of state/wear sensor
6
Accessories - Sensor
6.1
Technical Data „State/wear sensor“
6.2 Assembly / start-up