KTR-STOP
®
M-xxx B-xx-xx
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
445102 EN
21 of 22
3
Please observe protection
note ISO 16016.
Drawn:
2020-03-25 Shg/Wie
Replacing:
KTR-N dated 2019-08-26
Verified:
2020-03-25 Shg
Replaced by:
Operation of sensor
There are two micro switches in the housing of the
sensor. The spacer pin activates the switches in two
different positions.
Illustration 17:
State/wear sensor
Table 5: Switching status of status (switch S1) and wear switch (switch S2) depending on the activating
status of the brake.
Status of brake
Status of brake
pad
Switch S1
Switch S2
Illustration 18: Switch position
(status signal
on/off)
1)
(wear signal)
1)
1 - 4
2)
2 - 3
2)
2 - 5
2)
Sensor not moun-
ted
-
0
0
1
Brake not acti-
vated (unlocked)
-
1
1
0
Brake activated
(locked)
No wear
0
1
0
Resetting neces-
sary
0
0
1
1) Status of brake
on
= brake unlocked
off
= brake locked
2) Switch position
0
= unlocked
1
= locked
Switch S2 only shows the wear status reliably when the brake is activated (locked). If the brake is not activated
(unlocked), a statement about the condition of wear cannot be given.
The wear of the brake pad is only measured if the brake is activated. If the brake is not acti-
vated, there is no signal.
„Resetting necessary“ is displayed as soon as the brake pad has worn off in a way that re-
setting has become necessary.
!
The brake pad has to be reset as soon as the signal status „resetting necessary“ is acti-
vated.
Brake pads having a balance of pad height of less than 2 mm have to be replaced by return.
Please note chapter 5.1 Replacement of brake pads.
Fail-safe operation
A proper operating condition is only ensured if the state/wear sensor is wired properly. This provides a signal
since a switch (NO) is locked which is normally unlocked.
!
In case of damages like, for example, faulty cables, bad connections, etc. the signals need
to disappear.
6
Accessories - Sensor
6.1
Technical Data „State/wear sensor“