EN
48
WIRELESS KEYPAD
It’s possible to add new wireless Keypads to the System or to modify the setting of those wireless
Keypads which are already part of the System. The programmable parameters are the following:
Description: name associated to the device.
Serial Number: on each wireless device there is a label with serial number which can be used to
identify it.
Two devices of the same type can not have the same serial number.
AUDIO ALERT IN/OUT
If this option is enabled, the ergo wls keypad reports the exit time and the system entry time
NOTE: at the end of the control panel programming, if there are ergo wls keypads, it’s necessary to
carry out a first activation of the mentioned devices to display the status of the system (example by
typing the Enter key), so that the keyboards work according to the configuration.
REPEATERS
Here it’s possible to add new ‘duo’ or ‘ergo’ wireless Keypad enabling the Repeater mode Repeaters
to the System or to modify the setting of the Repeaters which are already part of the System.
The programmable parameters are the following:
Description: name associated to the device.
Serial Number: on each wireless device there is a label with serial number which can be used to
identify it.
Two devices of the same type can not have the same serial number.
ADDRESS BOOK
In here you can save up to 8 contacts the whom to send all the notifications defined during setting.
The parameters for each contact are the following:
Description: name associated to the contact.
Phone number: it’s the number to whom to forward all the calls and/ot SMS configured ( see below).
The sign ‘,’ means a pause of 1 second and can be used if the PSTN Interface is linked to an
automatic answering machine. Assuming that the machine foreseen a ‘0’ to engage the outcoming
urban line and that the number to call is of the type1234567890, the Installer can program the
following number ‘0,1234567890’. In the moment that the Panel has also the GSM/GPRS module and it
needs to call the same number, every figure until the ‘,’ included will be ignored.
e-mail Address: this is the address which will be adopted for forwarding all events, without any
additional setting.
Alarm Action: it allows the choice of the event type which has to be forwarded to this contact in case
of any Alarm. The possible options are: “No Action”, “Call”, “send SMS” or “send SMS and Call”
Tamper Action: it allows the choice of the event type which has to be forwarded to this contact in
case of any Alarm. The possible options are: “No Action”, “Call”, “send SMS” or “ send SMS and Call”
Fault Action: it allows the choice of the event type which has to be forwarded to this contact in case
of any Alarm. The possible options are: “No Action”,“send SMS”
Scenario Action: it allows the choice of the event type to be forwarded to this contact at the
activation of a scenario from Keypad or Remote Control. The possible options are: “No Action”, “Call”,
“send SMS” or “send SMS and Call.
CODES
It’ s possible to set-up the User Codes. For each Code the following parameters can be programmed:
Description: name associated to the device.
Enabled: select this option to enable the Code. Furthermore is it possible to set-up the access PIN (6
Digits).
RFID TAGS
It’ s possible to add new RFID or modify the setting to those already existing.
These are the programmable parameters:
Description: name associated to the device.
Enabled: select this option to enable the Key
NOTE: the Key acquisition must be made from the incorporated Keypad or the one remoted by BUS
only.