![Ksenia lares wls 96-IP Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/ksenia/lares-wls-96-ip/lares-wls-96-ip_installation-use-and-maintenance-manual_2006760035.webp)
EN
35
INTRODUCTION
The ’lares wls 96-IP’ Control Panels utilize a last generation Wireless 868 MHz Technology completely
BI-DIRECTIONAL and fully encrypted. This allows the best reliability since each Peripheral continue to
notify the signal to the Panel until his signal reception will be acknowledged . The maximum protec-
tion will be guaranteed also thanks to the encryption of all messages exchanged between Panel and
Peripherals. Complex Management Algorithms of the Transmission Power according to the distance
Panel to Wls. Peripheral enable long Battery Lifes and contemporary strong Interference reduction.
With lares wls 96-IP you have the possibility to program and manage the System by means of Ksenia
SecureWeb on top of the standard modes via Keypad or PC. SecureWeb, in fact, provides the Installer
with a dedicated APP named Secureweb- KSENIA PRO which allows the Panel Configuration from any
mobile devices (smart phones incl.). Just by a simple scan of its QR-code, the Panel gets registered
with geo-localization and receives Push Notifications.
Download the APP by using the QR-code printed on the Packaging or follow the instruction given at
Pag.11.
HARDWARE CHARACTERISTICS PER MODEL/ DATA-SHEET
CONTROL PANEL MODEL
lares wls 96-IP
Power Supply
230 V~ -15/+10% 50 Hz 0,3A
Power Supply/Battery Charger (Type A Norm EN50131-6)
14,2V ± 1% 1,7A
Consumption (max)
100mA
Max. Current available for powering other optional PCBA
or External Devices.
600 mA grado 2
Max. Ripple Voltage on Outputs
120 mV
Max. Recharging Current
600 mA
Max. Time for recharging 80% of Battery
3 h
Battery Deep Discharge Disconnection Voltage
10 V
Min. Voltage for generating Low Battery Fault (restore)
11,5 V (13,1 V)
Min. Voltage for generating Low Power Supply Fault
(restore)
12 V
Back-up Battery KSI7212020.000 (not included)
2 Ah
On board Wired Inputs
4
Max. Output numbers OC + Wireless
2 + 16
Faulty Supply Signal
SI
Over-voltage Protection
SI (1,7 V)
IP Protection Degree
IP 30
Security Degree
2
Environmental Class
II
Insulation Class
I
Dimensions (W x H x T)
297 x 222 x 58
Weight (with Battery)
2,0 kg
Indoor Siren
Integrated
Max. Repeater Nr.
2
Max. Remote Control Nr.
16
Operative Temperatures
-10 / +55 °C
Humidity
95 %
Conformity
CE • EN50131-1 • EN50131-3 • EN50131-6 • EN50136-1-1