![KSB Hya-Solo DV Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/ksb/hya-solo-dv-series/hya-solo-dv-series_installation-and-operating-manual_2006480016.webp)
NOTE
The housing cover must not be opened.
Non-compliance will result in forfeiture of any and all warranty claims.
Removing the L-shaped
cover.
Remove the cross-head screws on the L-shaped cable cover for the control cables and
remove the cover.
Removing the V-shaped
cover.
Remove the cross-head screws on the V-shaped cover for the mains and motor connection
and remove the cover.
Route the power/motor cable through the cable glands (as shown in table 20, section
6.4.6) and connect them to the appropriate terminals (see Fig. 10 and Fig. 11).
When closing the covers, make sure that the sealing elements are properly seated.
NOTE
The screws fastening the cover of the mains and motor terminal box must be tightened to
a torque of 1.2 Nm to ensure that the device has IP55 enclosure protection.
DANGER
Open terminals and connectors of brake resistor.
Danger to life!
▷
Do not open the terminals and connectors of the brake resistor.