Preface 

 

     Scaler /Polisher unit is developed based on the Principle of piezoelectric 
Ultrasonic waves are generated in the handpiece by 4 ceramic piezoelectric plates 
subjected to high frequency alternation current. The Tip is vibrated back and forth 
in high speed to perform tooth calculus and/or tartar cleaning task.  Particularly, 
the high speed vibrated Tip can remove the toughest calculus and tartar easily, and 
in conjunction with syringe (or saliva ejector), the scaler can conveniently and 
swiftly clean teeth and most importantly it is proven to be electrically safe.    The 
electric-mechanical efficiency of this piezoelectric system is much greater than that 
of traditional magnetostrictive systems. There is very little heat released, and it is 
possible to work with very little spray. It’s sufficient to ensure excellent cavitation 
but more comfortable for both the patient and the dental surgeon. 

The ART-SP2 is a very powerful apparatus. There are linear scales of 

power adjustment for removing prostheses and condensing gutta-percha. This 
allows very fine adjustment to suit each clinical situation. 
With a large range of Tips, the ART-SP2 is suitable for different kinds of work.   

 
 
ART-SP2 
 

 

Operation Frepuency:29 KHz 

 

Stable and Fine Power Setting 

 

Various Types of TIP Available 

 

No Heat Generation of Handpiece 

 

Automatic Feedback Control and Powerful Torque 

 

High Torque Feature even at the Speed condition 

 

0~2,000 RPM of Speed Control 

 

Scaler and Polisher in one Equipment 

 

 

Special notes to doctor: 

Since the TIP of scaler is made of stainless steel, avoid direct contact to patient's 
teeth; it may damage to the enamel of the teeth.    To better utilize all the functions 
and maximize the performance of the scaler, it is suggested that before using on 
patients, doctors should practice on models/aluminum plates to familiarize 
themselves with the usage of the scaler tips and the subtle motion and force of the 
insert, etc. 

 

 

Содержание 271390

Страница 1: ...Instruction Manual KRUUSE ART SP2 Piezo scaler and micromotor Cat No 271390 J RGEN KRUUSE A S Havretoften 4 DK 5550 Langeskov Tlf 45 7214 1511 Fax 45 7214 1400 www kruuse com I...

Страница 2: ...ends to enforce its rights to this manual under copyright law No one may copy the materials presented in this manual without the express written permission of BONART MEDICAL TECHNOLOGY INC Product spe...

Страница 3: ...MENTS NOTE Indicates some tips CAUTION Indicates correct operating or maintenance procedures in order to prevent damage to or destruction of the equipment or other property WARNING Calls attention to...

Страница 4: ...ment ART SP2 should be powered from a separate wall outlet with grounding point Attention Avoid use of this machine around Pacemakers It has been shown that electronic appliances including razors hair...

Страница 5: ...y degrade the performance and or may accidentally cause damage to the system Do not dismantle the machine on your own or by uncertified technicians Violation of the requirement may cause harm to the u...

Страница 6: ...or both the patient and the dental surgeon The ART SP2 is a very powerful apparatus There are linear scales of power adjustment for removing prostheses and condensing gutta percha This allows very fin...

Страница 7: ...ents 2 Descriptions of Components 2 Description of Control Panel 4 II Installation Guide 6 III Preparation and Practice before the First Use 9 IV Operation Procedures 11 V Maintenance 13 VI Cleaning a...

Страница 8: ...Handpiece consists of vibrator and a Tip The vibrator is composed of four pieces of piezoelectric plates It generates displacement when driven by the electrical signal from the Main Unit The vibrator...

Страница 9: ...thout interrupting the cleaning process at hand 4 Water Tubing 5 AC Line Socket Seat 6 Micro Motor This is a DC micro motor Micro motor speed will be reacted from input voltage reacted Please see page...

Страница 10: ...ater volume control knob doctors can conveniently adjust water volume based on the operation needs It is noted that not only washing away the dirt left from the calculus and or tartar water here is al...

Страница 11: ...t up It means the operation is under Polishing model During this model the micro motor output power will increase If pushed the button again the operation model will back to scaling model 5 BF symbol...

Страница 12: ...ental limitations apply to both storage and shipping Temperature 0 to 60 Humidity 10 90 at 40 Atmospheric pressure 860 1060 hPa B Labels The meaning of labels printed on the outside of the package box...

Страница 13: ...e unit from the line Remove the cover of the fuseholder by means of a small screwdriver Fit a new fuse of the correct rating and refit the cover of the fuseholder The fuse will be 2A 250V delay action...

Страница 14: ...oper micro motor Several installation suggestions are listed below 1 Because patients may experience some tissue trauma during the treatment it is suggested that the operator use purified or distilled...

Страница 15: ...power intensity by turning the power knob Familiarize yourself with the differences when changing the output power intensity Finally adjust the water volume by turning the water volume control knob F...

Страница 16: ...C Tangential Application E3 TIP Contact on the enamel with the rounded Ttip without pressure when movement 10...

Страница 17: ...hair angle and or position so that you can easily access to the patient s oral cavity 2 Put the saliva ejector into patient s mouth to evacuate away excessive saliva and cleaning remainders 3 Gently m...

Страница 18: ...ained When preparing to execute Polishing model 1 Check the micro motor connection and pushed the MICRO MOTOR change to Polishing model 2 The Forward Reverse that locates rear panel is controlling the...

Страница 19: ...erilized The following suggestions are also useful in extending the product life of the unit A Place the Main Unit in an open area where air can flow freely around it B If need to move the Main Unit h...

Страница 20: ...of the system At the end of the day with the Tip remove the handpiece and cable should be scrubbed with an antiseptic soap or solution and rinsed off with water The handpiece should be scrubbed a seco...

Страница 21: ...reduce the power output Note Replace one new Tip if you find damage worn or weak power of the Tip Main Unit Since the Main Unit does not have direct contact with the patients the cleaning is simple J...

Страница 22: ...AC Power Line x1 3 Three way switch x1 4 PU Tube x1 5 TORQUE WRENCH SET BOX x1 6 Piezo Handpiece x1 7 E5 E2 E3 TIP 8 E type Micro motor Optional Note The above standard outfit is subject to change de...

Страница 23: ...N60555 3 Immunity IEC 1000 4 2 IEC 1000 4 4 IEC 1000 4 5 IEC 801 3 ENV50141 Safety IEC 60601 1 EN1640 2 Function List Scaler power control Water flow control Footswitch control Polisher mode 3 Specifi...

Отзывы: