11.3
Calibrating the Sensor – with Electrical Rotor Height Adjustment Design
Pos: 35.26.2 /BA/Ei nstellungen/Schwader/Sensor kalibri eren - Einl eitung @ 359\mod_1439198670211_78.docx @ 2662277 @ @ 1
The calibration only works if sensor voltage is less than 1 V (bottom stop) or greater than 4 V
(upper stop).
If this is not the case, consult KRONE specialist workshop so that the sensor can be readjusted
mechanically until the voltage values are again in the permissible range.
• Park machine on level and firm ground so that both rotors are parallel to the ground.
• Set the rotors to the least working height. In doing so, make sure that both rotors have the
same distance to the ground.
Due to allowed deviating tolerances of parts, the displays may contain different values before
calibration is performed.
Pos: 35.26.3 /BA/Ei nstellungen/Schwader/Sensor kalibri eren - Bild_Variante Plus_TC 880 @ 391\mod_1445844115872_78.docx @ 2799436 @ @ 1
2
1
SW900050
Fig. 49
Pos: 35.26.4 /BA/Ei nstellungen/Schwader/Sensor kalibri eren - Anzeigen nullen und Kali brier vorgang @ 391\mod_1445846105479_78.docx @ 2799563 @ @ 1
Resetting the displays to zero
• Lay permanent magnet on the display.
Calibration was successful
when the display flashes three times
.
If the display does not flash
, perform calibration again.
Calibration process
• Move each of the both rotors down to the ground.
• Hold permanent magnet over the right display (1).
The right display flashes for approx. 5 seconds.
After that measurement value 0 is saved as lower limit of measuring range.
• Remove magnet.
• Hold permanent magnet over the left display (2).
The left display flashes for approx. 5 seconds.
After that measurement value 0 is saved as lower limit of measuring range.
• Remove magnet.
• Raise both rotors to headland position and raise rotor height adjustment until the stop is
reached.
• Hold permanent magnet over the right display (1).
The right display flashes for approx. 5 seconds.
After that measurement value 99 is saved as upper limit of measuring range.
• Remove magnet.
• Hold permanent magnet over the left display (2).
The left display flashes for approx. 5 seconds.
After that measurement value 99 is saved as upper limit of measuring range.
• Remove magnet.
Pos: 35.27 /Layout Module /---------------Seitenumbr uch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Содержание Swadro TC 1000
Страница 2: ...Table of Contents 2 Pos 2 Layout Modul e Seitenumbruch 0 mod_1196175311226_0 docx 4165 1 ...
Страница 97: ...Maintenance lubrication 97 Lubricate the lubrication points every 20 operating hours 7 8 9 10 11 12 13 ...
Страница 112: ...K3 K1 K2 10 l min 10 l min 10 l min 10 l min A A1 A3 A2 P MP 1 2 2 R L R L 150101521_03 1 5 4 2 ...
Страница 115: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ WZLQ URWRU UDNH FHQWUH VZDWKLQJ 6ZDGUR 7 7 1 ...
Страница 121: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ WZLQ URWRU UDNH FHQWUH VZDWKLQJ 6ZDGUR 7 3OXV 1 ...
Страница 131: ......