23
Malfunction, cause and remedy
23.1
Malfunctions electrics/electronics
320
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
Possible cause
Remedy
The wiring of the actuator is
faulty.
Check actuator and wiring for damage,
.
522346-
K13
Actuator K13 “Cutting rotor safety valve“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522535-
RMC
Control unit moisture measurement (RMS)
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522536-
RMC
Control unit moisture measurement (RMS)
Possible cause
Remedy
FMI 31: The condition has been fulfilled.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522537-
RMC
Control unit moisture measurement (RMS)
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
The wiring to KMC is faulty.
Check wiring for damage.
One or more sensors/actuat-
ors connected to the voltage
group are defective.
There is an overview of the position of the sensors,
actuators and control units in the circuit diagram,
Check sensor and wiring for damage,
.
The control unit is defective.
Replace the control unit.
522538-
RMC
Control unit moisture measurement (RMS)
Содержание Big Pack 1290 HDP
Страница 345: ...II T P LS I III IV T P S1 S2 M1 M2 V1 V2 P1 B1 A1 B2 B1 T1 T T4 P 180 bar B36 100 bar B11 B35 150101911_00 2 4 ...
Страница 347: ...B17 K9 K11 K12 B B1 A A1 1 2 3 K13 3 4 5 1 2 150101911_00 3 4 ...
Страница 349: ...B17 K11 1 2 150101911_00 4 4 ...
Страница 351: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ ODUJH VTX XDUH EDOHU L 3 LJK 6SHHG XW 9DUL XW 3 3 1 0HGLXP RPIRUW IURP PDFKLQH QR ...