16
Settings
16.20 Checking/setting Variable Filling System (VFS)
230
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
16.20.4
Setting the rubber pad on the zero adjuster
BP000-236
ü
The machine is shut down and safeguarded,
.
ü
The Variable Filling System (VFS) is in zero position,
.
Place or remove washers under the rubber buffers (16) until the dimension is
X=0–2 mm
.
16.20.5
Checking/setting spring at zero adjuster
BP000-237
In the factory, the spring (2) is set to dimension
X=185 mm
.
ü
The machine is shut down and safeguarded,
.
ü
The Variable Filling System (VFS) is in zero position,
.
Check dimension X.
ð
If the dimension is
X=185 mm
, the setting is correct.
ð
If the dimension is
not X=185 mm
, the spring (2) must be set.
Set the spring (2) to dimension
X=185 mm
.
Содержание Big Pack 1290 HDP