Malfunction, cause and remedy
23
Malfunctions electrics/electronics
23.1
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
295
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
The total baling force on the
machine has been exceeded.
In manual mode:
Reduce the target baling flap pressure.
In automatic mode:
If the alarm occurs frequently, reduce the target baling
force.
522022-
L>MAX
Baling force on the left
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
The baling force on the left
baling flap has been ex-
ceeded.
In manual mode:
Reduce the target baling flap pressure.
In automatic mode:
If the alarm occurs frequently, reduce the target baling
force.
522023-
R>MAX
Baling force on the right
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
The baling force on the right
baling flap has been ex-
ceeded.
In manual mode:
Reduce the target baling flap pressure.
In automatic mode:
If the alarm occurs frequently, reduce the target baling
force.
522024-
Lower twine
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
The lower twine is torn.
Check the twine and the twine tensioner.
522025-
1
Upper twine 1
Possible cause
Remedy
FMI 1: The lower limit value was far below the required one.
On the upper twine, the min-
imum twine length has not
been reached when trying to
tie a knot.
Check the knotter and the knotter triggering.
Have the sensor adjusted.
522026-
2
Upper twine 2
Содержание Big Pack 1290 HDP
Страница 345: ...II T P LS I III IV T P S1 S2 M1 M2 V1 V2 P1 B1 A1 B2 B1 T1 T T4 P 180 bar B36 100 bar B11 B35 150101911_00 2 4 ...
Страница 347: ...B17 K9 K11 K12 B B1 A A1 1 2 3 K13 3 4 5 1 2 150101911_00 3 4 ...
Страница 349: ...B17 K11 1 2 150101911_00 4 4 ...
Страница 351: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ ODUJH VTX XDUH EDOHU L 3 LJK 6SHHG XW 9DUL XW 3 3 1 0HGLXP RPIRUW IURP PDFKLQH QR ...