Running a concentric flue and air duct through the side wall of the building -
type C31:
Moving through the roof can be carried directly vertically. The minimum length of the
vertical section without a knee is 1 meter, while the maximum length may not exceed
10.0 meters (Figure 9). This is possible to use two 45 degrees elbows in such
installation. All variant possible for this type of venting system are described above.
Fig. 9. Leading concentric chimney system through the roof
Running a concentric flue and air duct through the side wall of the building -
type C91:
It is also allowed to install the device using the existing chimney. It is an installation
analogous to type C31, but with the use of elements of an existing chimney installation.
However, special requirements must be met for this purpose:
✓
Piping a pipe with 100 mm diameter for the discharge of flue gas through the
existing chimney to the terminal at the end of the chimney. The space inside the
existing chimney serves only to provide combustion air.
✓
The cross section of the existing chimney must be not less than 150 x 150 mm.
✓
The length of the chimney should not exceed 3 m.
✓
The existing chimney should be clean and easy to maintain.
✓
The existing chimney should be unobstructed and sealed.