12
INSTALLATION REQUIREMENTS.
Fig. 3. Minimum distances of the gas cartridge from non-combustible housing elements
The distances indicated above are the minimum distances from a non-flammable
housing, unless another provision states otherwise.
The main reason for fires associated with the fireplace is the lack of maintenance of
the required distances (free air space) from the walls of the housing. It is very important
that this fireplace and ventilation system is installed in accordance with these
instructions.
WARNING:
There is a great risk of fire hazard if the gaps specified in this manual are not observed.
The device is designed and approved for use with a non-flammable housing as shown
in the diagrams with an interval of min. 6 cm on the back and sides of the device, if it
is not a version with side glazing. To adapt to different thicknesses of bodywork
finishing materials, please follow the instructions below.
The material used for the installation must not transfer weight to the device or be
connected to the device in any way. They must not cover any part of the removable
glass panel or control system.
The total thickness of the non-flammable building material must be determined so that
the surface can be flush with the front of the device. The total thickness of the cladding
can be from 15 mm to 30 mm.
WARNING:
Consider installation because there must be no flammable materials at a
distance of at least 60 cm from the device.
Inspection doors -
are required in all LEO gas fireplace inserts. They allow efficient
and convenient access to the receiver and the control valve of the device, which are
necessary for the proper operation of the device. The inspection door has been
designed and should be installed in a place that does not disturb the aesthetics of the
finish of the fireplace or the surrounding living space. The service technician should
also service the gas controls of the device passing through the device itself. This
procedure requires removing the glass panels, removing the decorative elements of