In the event of condensation in the chimney flue, the installer should use a drainage
element (droplet separator). Each elbow used for the exhaust air exhaust system is
counted as a meter length and this should be taken into account when calculating the
total length of the exhaust air duct. All concentric system channels cannot be isolated.
When routing the chimney through the external wall or roof of the building:
➢
Install the system in accordance with applicable regulations, taking into account
any difficulties associated with wind pressure on the terminal.
➢
In the case of a flammable wall, ensure an additional distance of 5 cm between
the wall and the outer surface of the coaxial pipe. Fill in the remaining space
with thermal insulation, which additionally prevents moisture from entering the
building.
➢
If the flue pipe is close to flammable walls, secure them with a minimum of 25
cm thermal insulation.
➢
Begin installation of the concentric system by installing a one-meter vertical
section at the outlet of the fireplace (minimum height).
➢
Connect the individual elements of the system using special straps to ensure
proper tightness.
➢
If necessary, stabilize the individual components of the concentric system using
wall brackets.
➢
The coaxial cable must be terminated with a windproof terminal. A special
horizontal terminal is used when leading through a wall (type C11), while a
vertical terminal (type C31) is used when leading through a roof.