SECTION 9
ELECTRICAL INFORMATION
Electrical Specifications–Wiring Requirements
#SP-41-L
R.6 February 2022
#SP-41-L
R.6 February 2022
36
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
9.0 ELECTRICAL INFORMATION
WARNING: Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect this appliance
and to replace any part of the control system and any gas control which
has been under water.
WARNING - Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
9.1 Electrical Specifications
This appliance, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
9.2 Wiring Requirements
The wiring diagram for this appliance is shown in
below.
•
The Komfort 8K1 system requires 120 VAC of electricity and/or
batteries to operate.
•
Using the battery backup will operate flame modulation of
the burner.
•
Optional fan component will not function on battery
backup power.
BLACK
BLA
CK
RED
RED
RED
RED
BR
OWN
GROUND
EV2
GREEN
(MAIN)
EV1
ORANGE
(PILOT)
MALE END
AUX 3
(FAN)
RED BOOT
(FLAME SENSOR)
BLACK BOOT
(IGNITER)
MALE END
6V DC
TRANSFORMER
KOMFORT 8K1
CONTROL MODULE
PILOT
FAN
BATTERY PACK
6V DC
(with 1 amp fuse)
DEXEN MH3V
GAS VALVE
AUX 300
ON/OFF
ROCKER SWITCH
FIGURE 9.1
Wiring Schematics