kozy heat SLA-60 Скачать руководство пользователя страница 52

52

  LIMITED LIFETIME WARRANTY

Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces

#SLA-60 R.8 March 2022

LIMITED LIFETIME WARRANTY

Warranty Coverage

Hussong Manufacturing Company, Inc. (Hussong Mfg.) warrants this 

Kozy Heat gas appliance from the date of purchase to the original 

purchaser, that it is free of defects in materials and workmanship at 

the time of manufacture. Registering your fireplace warranty does not 

require any documents to be sent in to Hussong Mfg. Please retain 

your proof of purchase reflecting the date of purchase along with the 

serial number and model of your fireplace for any future warranty 

claims.

If a defect is noted within the warranty period, the customer should 

contact their authorized dealer for service within 30 days.

30 Days: Parts & Labor*

• 

Paint

• 

Light bulbs

• 

Gasket material 

• 

Glass media and media dam

Year 1: Parts & Labor*

• 

All parts and material except the items listed in the 30 day 

warranty and any exclusions or limitations that may apply.

*Hussong Mfg. will issue labor reimbursement to an authorized dealer 

only. Hussong Mfg. will not be liable for charges occurred as a result of 

any service performed by a non-authorized service provider, without 

pre-authorization. 

Years 2 through Lifetime: Parts Only

• 

Firebox

• 

Heat Exchanger

• 

Logs

• 

Burner tube or pan

• 

Outer shell

• 

Heat shield(s)

• 

Front Viewing Glass (thermal shock only)

• 

Refractory Firebox liner (excluding enamel and glass panels)

EXCLUSIONS AND LIMITATIONS

1.  This appliance must be installed by a licensed, authorized service technician or contractor. It must be installed, operated and maintained 

at all times in accordance with the instructions in the owner’s manual or the warranty is void.

2.  This warranty is nontransferable and is made to the original purchaser only.
3.  This warranty excludes standard wear and tear of the appliance which is considered normal usage over time.
4.  Discoloration and some minor expansion, contraction or movement of certain parts, resulting in noise, is normal and not a defect.
5.  Warranty is automatically voided if the appliance’s serial number and/or testing label is removed or if the appliance is altered or 

tampered with in any way.

6.  Warranty is void if the appliance is subject to submersion in water or prolonged periods of dampness or condensation. Any damage 

to any part of the appliance due to water or weather damage which is the result of, but not limited to, improper chimney/venting 

installation will also render this warranty void.

7.  This warranty does not cover installation and operational related problems such as environmental conditions, nearby trees, buildings, 

hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures caused by any mechanical systems.

8.  Chimney components and other Non-Hussong Mfg. accessories used in conjunction with the installation of this appliance are not 

covered under this warranty.

9.  Damage to plated surfaces or accessories, if applicable, caused by scratches, fingerprints, melted items or other external sources left on 

the surfaces from the use of cleaners is not covered under this warranty.

10.  It is expressly agreed and understood that this warranty is Hussong Mfg.’s sole obligation and purchaser’s exclusive remedy for defective 

fireplace equipment. Hussong Mfg. is free of liability for any damages caused by this appliance, as well as inconvenience expenses 

and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or 

consequential damage may not apply. Hussong Mfg. shall not be held to implied warranties and this warranty shall replace all previous 

warranties.

11.  This limited lifetime warranty is the only warranty supplied by Hussong Mfg. Any warranties extended to the purchaser by the dealer/

distributor, whether expressed or implied, are hereby disclaimed and the purchaser’s recourse is expressly limited to the warranties set 

forth herein.

12.  Any part repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period 

not to exceed the remaining term of the original limited warranty.

13.  Any replacement part repaired after the warranty period will include a 90 day parts coverage
14.  Hussong Mfg. may require the defective part to be returned using a pre-authorized RGA number or a photo of the defective component. 

Failure to provide either can result in a denied claim.

15.  This warranty does not cover the appliances ability to heat a desired space, as there are many factors that can impact the heating 

performance in each home. Consideration should be implied to the appliance’s location, room size, home design, environmental 

conditions, insulation, and tightness of the home.

16.  Hussong Mfg. reserves the right to make changes at any time, without notice, in design, material, specifications, and prices. Hussong 

Mfg. reserves the right to discontinue models and products.

July 2018

Содержание SLA-60

Страница 1: ...ome USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other g...

Страница 2: ......

Страница 3: ...ty but also customer safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Boa...

Страница 4: ......

Страница 5: ...Clearances 24 7 0 VENTING 25 7 1 Approved Vent Systems 25 7 2 Venting Requirements 25 7 3 Elbows 25 7 4 Restrictor Plate Assembly and Installation 25 7 5 Vertical Terminations 26 7 6 Combination Vent...

Страница 6: ......

Страница 7: ...eriod a battery operated carbon monoxide detector with an alarm shall be installed 1 3 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provi...

Страница 8: ...Installation Code local authorities or codes having jurisdiction in you area regarding derate guidelines 2 1 1 1 US Installations Refer to the American Gas Association guidelines for the gas designed...

Страница 9: ...60 R 8 March 2022 Hussong Mfg Co Inc Kozy Heat Fireplaces SPECIFICATIONS 9 2 3 Appliance Dimensions TOP FRONT LEFT SIDE RIGHT SIDE GAS LINE HOLE GAS LINE HOLE ELECTRICAL ACCESS Figure 2 1 SLA 60 Dimen...

Страница 10: ...rim kit assembly for use only with safety barrier SL60 RSF will allow you to install finishing material up to the finishing edge Refer to Section 4 2 Optional Trim Kit Assembly SL60 FTK on page 21 The...

Страница 11: ...5 in 147 mm minimum clearance to the header Use only non combustible material in this area for the entire width of the fireplace DO NOT use wood sheetrock et cetera in this zone Top stand off brackets...

Страница 12: ...replace with the stand off flanges on the nailing flanges facing away from the fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend...

Страница 13: ...ombustibles Table 3 1 Minimum Appliance Clearances to Combustible Material From appliance top stand offs 0 in 0 mm From appliance left and right side stand offs 0 in 0 mm From appliance back stand off...

Страница 14: ...on carpeting tile or other combustible material other than wood flooring this appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance This fireplace m...

Страница 15: ...must be used This will increase the minimum heightforthecenteroftheventpipeby3 1 4 83mm whenframing the wall pass through NOTE Kozy Heat s 800 WPT3 or wall thimble products that comply with the requi...

Страница 16: ...outdoor covered fireplace installation allows a fireplace to be installed in an outdoor covered area where the appliance is protected from direct precipitation Follow the instructions and illustration...

Страница 17: ...A T H E R P R O O F O V E R H A N G I N F R O N T A N D S I D E S MINIMUM WEATHERPROOF OVERHANG IN FRONT AND SIDES M I N I M U M W E A T H E R P R O O F O V E R H A N G I N F R O N T A N D S I D E S F...

Страница 18: ...e This fireplace is designed to accommodate non combustible facing material up to 1 2 in 13mm thick Install facing material up to the finishing edge that surrounds the glass frame assembly Do not appl...

Страница 19: ...o Inc Kozy Heat Fireplaces FACING AND FINISHING 19 17 483mm 14 362mm 40 1022mm 313 16 792mm 62 1581mm EACH SQUARE REPRESENTS 1 25mm OF MANTEL PROJECTION FINISHING EDGE COMBUSTIBLE FLOORING 12 305mm 9...

Страница 20: ...TERIAL ALLOWED COMBUSTIBLE MATERIAL ALLOWED NO SCREWS ABOVE FRAMING LOWER COVER PANEL COMBUSTIBLE MATERIAL ALLOWED NO SCREWS ABOVE FRAMING BOTTOM 19mm 63 1600mm 11 292mm 19mm 5 140mm 87 8 225mm 617 16...

Страница 21: ...frame assembly There are 5 holes above and 5 holes below the fireplace opening and 3 holes on each side 2 Align the top and bottom trim panels with the pre drilled holes on the fireplace face Positio...

Страница 22: ...3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A listed and Commonwealth...

Страница 23: ...30 Over 6 12 to 7 12 1 25 0 38 Over 7 12 to 8 12 1 5 0 46 Over 8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52...

Страница 24: ...building or the combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachuset...

Страница 25: ...red 1 in 25 mm clearance to combustibles must be installed for all horizontal vent runs that pass through interior or exterior walls These wall thimble products may be insulated using unfaced insulati...

Страница 26: ...listed as non combustible per ASTM E 136 Table 7 1 NG Propane Minimum Maximum Vertical Terminations Minimum Vertical Length Maximum Vertical Length 3 ft 914 mm 50 ft 15 2 m Minimum Maximum Vertical V...

Страница 27: ...al Vent Pipe Minimum Horizontal Vent Pipe Maximum Horizontal Run 12 in 6 in 305mm 152mm 9 in 229 mm 36 in 914 mm Minimum Vertical Vent Pipe Min Max Horizontal Terminations 12 6 305mm 152mm minimum ver...

Страница 28: ...tical Vent Pipe Minimum Horizontal Vent Pipe Maximum Horizontal Run 24 in 610 mm 9 in 229 mm 24 in 610 mm Minimum Vertical Vent Pipe Min Max Horizontal Terminations 24 610mm vertical vent pipe 90 hori...

Страница 29: ...overlap a minimum of 1 1 2 38mm Secure to exterior wall with 4 screws not provided 7 7 2 Vent Assembly and Installation 1 Mount the required 800 WPT3 G or a wall thimble that complies with the require...

Страница 30: ...the fireplace 3 Secure the vertical vent heat shield to the fireplace with 2 attachment screws provided in the components package 7 8 2 Minimum Horizontal Venting 1 Bend perforation on the 3 hand tab...

Страница 31: ...the firebox while lowering the bottom of the glass assembly into position 2 Pull the spring loaded latches out and up to secure the bottom of glass to the bottom of the fireplace 3 Reinstall valve acc...

Страница 32: ...Remove 75 of the crushed glass covering the burner ports Do not block the pilot assembly 4 Save any unused media for later use 8 3 3 311 Series Glass Media Installation 1 Remove glass media from its p...

Страница 33: ...ove assembly from firebox 10 Remove and save 12 screws securing the control board 11 Lift the control board out of the firebox being careful not to damage sealing gasket underneath 8 4 2 Control Board...

Страница 34: ...must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 9 2 Wiring Requir...

Страница 35: ...4 When the motor end clears the fireplace face turn the fan to the left FIGURE 9 2 5 Rotate the top end down and to the right lowering the fan into control compartment FIGURE 9 3 6 Position fan as sho...

Страница 36: ...nce 10 Press the wireless remote POWER button 11 If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTR...

Страница 37: ...e will operate on the backup battery pack in a power outage The lifespan of the backup batteries depends on various factors such as the quality of the batteries number of ignitions etc There is a cut...

Страница 38: ...TE switch to ON The control module will illuminate a green LED 2 times and emit a beep The ignition sequence will start again 10 7 Additional Diagnostic Information Diagnostic codes are outlined below...

Страница 39: ...control will go into a standby mode if no buttons are pressed within 5 minutes Press the POWER button to reactivate the remote control to ON mode Active functions will be displayed once in ON mode PO...

Страница 40: ...e beep will confirm the reception of the command 10 8 7 Pilot Ignition Selection Intermittent or Pilot on Demand This system has the option of a pilot on demand allowing the system to change from a sp...

Страница 41: ...the room temperature drops below the set temperature 10 8 10 Fan Speed Control optional The fan speed can be adjust through 3 speeds HIGH MEDIUM LOW The fan is controlled by a timer built into the con...

Страница 42: ...in increments of 15 30 45 60 90 120 and 180 minutes To activate this function 1 Press the MENU button to activate the menu 2 Using the UP and DOWN arrows highlight the TIMER icon and press SELECT 3 Us...

Страница 43: ...nimum and maximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten...

Страница 44: ...rientation closing the air shutter will achieve a desired yellow flame but may produce soot on the glass Opening the air shutter will cause a short blue flame that may lift off the burner 11 2 1 1 Ven...

Страница 45: ...r installing and verifying correct vent installation shut off the gas supply and call a qualified service technician 11 2 2 1 Restrictor Plate Installation 1 Remove the safety barrier and the glass fr...

Страница 46: ...nnection Ensure batteries are fully charged if using battery back up as power source Use wiring schematic to determine that all wiring connections are secure and correct Control module selector switch...

Страница 47: ...ered ON and thermostat operation is turned OFF Pilot and burner extinguish while in operation No Propane in tank Check propane tank Refill if necessary Incorrect glass assembly installation Refer to S...

Страница 48: ...em Check the vent pipes for leaks and the vent cap for debris Repair the vent pipes or remove debris from vent cap if necessary No reaction to command Battery back up batteries or remote control batte...

Страница 49: ...tructions provided with installation Refer to Section 7 0 Venting on page 25 Performed by Qualified Service Person Frequency Annually Action Examination of the vent system is required The flow of comb...

Страница 50: ...f the flame safety system Pilot or Flame rectification device Visually check pilot light when in operation Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas va...

Страница 51: ...Natural Gas DEX 192 Conversion Kit Natural Gas NCK SL60 D Pilot Assembly Propane DEX 192 1 Conversion Kit Propane LCK SL60 D Dexen Transmitter Remote Control DEX RC3 Center Burner Tube SL60 C035 Pilot...

Страница 52: ...but not limited to improper chimney venting installation will also render this warranty void 7 This warranty does not cover installation and operational related problems such as environmental conditio...

Страница 53: ......

Отзывы: