#SLA-60 R.8 March 2022
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
FRAMING
13
TYPICAL HORIZONTAL INSTALLATION
TYPICAL VERTICAL INSTALLATION
TYPICAL CORNER INSTALLATION
3
3⁄16
”
(80mm)
19”
(483mm)
71
1⁄8
”
(1807mm)
3
3⁄16
”
(80mm)
19”
(483mm)
71
1⁄8
”
(1807mm)
110
1⁄8
”
(2797mm)
71
1⁄8
”
(1807mm)
32
1⁄8
”
(816mm)
55
1⁄16
”
(1398mm)
4”
(102mm)
77
7⁄8
”
(1977mm)
3.4 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-offs
0 in
0 mm
From appliance left and right side stand-offs
0 in
0 mm
From appliance back stand-offs
0 in
0 mm
From appliance bottom stand-offs
0 in
0 mm
From appliance corners
4 in
102 mm
From appliance front
36 in
914 mm
Top of finishing edge to ceiling
36 in
914 mm
Sides of finishing edge to adjacent sidewall
6 in
152 mm
Mantel 9 in (229 mm) deep from finishing edge
14-1/4 in
362 mm
Figure 3.3, Typical Install Options