#SLA-60 R.8 March 2022
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
ELECTRICAL INFORMATION
35
9.3 #SL42-028 Optional Fan Kit
ATTENTION: Installation of this fan kit should be done only by a qualified
installer.
WARNING: Verify household breaker is shut off prior to working on
any electrical lines. Disconnect all electric power from fireplace before
performing any of these tasks.
1. Remove safety barrier and glass frame assembly.
2. Disconnect wiring terminals from fan motors.
3. With the motor end of the fan’s right side facing down and to the
right, insert fan into chamber (
FIGURE 9.2
).
4. When the motor end clears the fireplace face, turn the fan to the left
(
FIGURE 9.2
).
5. Rotate the top end down and to the right, lowering the fan into
control compartment (
FIGURE 9.3
).
6. Position fan as shown in
FIGURE 9.3
. As you rotate the fan towards
you, the upper edge of the fan discharge will lock behind the top
edge of fireplace air channel opening, securing fan into place. DO
NOT LET THE FAN REST ON ANY ELECTRICAL CORDS.
7. Repeat for the left fan, noting the fan rotation in steps above will be
opposite of the right fan.
8. Reattach wiring terminals to fan motors.
9. Plug the fan cord into the AUX3 receptacle on the AUX 300 control
module. See
FIGURE 9.1
on page 34
10. Reinstall the glass frame assembly and safety barrier.
Figure 9.2, Steps 3 and 4
Figure 9.3, Steps 5 through 9