TROUBLESHOOTING
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#SLA-60 R.8 March 2022
Issue
Cause
Solution
Flame burns blue and lifts
off burner
Improper venturi setting
Venturi air shutter may need to be opened slightly to allow more air into
the gas mix. Refer to Section 11.2.1 Burner Venturi on page 44.
Incorrect vent cap installation
Adjust if necessary.
Blockage or leakage of the vent
system
Check the vent pipes for leaks, and the vent cap for debris. Repair the
vent pipes or remove debris from vent cap, if necessary.
No reaction to command
Battery back up batteries or
remote control batteries low
Replace batteries.
No communication between
remote control and control
module
Reprogram remote control to Komfort 8K1 module. Refer to section
10.2, INITIALIZWE THE KOMFORT 8K CONTROL SYSTEM
on page 37.
A maximum number of failed
ignitions or flam restorations has
been reached
Reset Komfort 8K1 control module. Refer to section
10.2, INITIALIZE
THE KOMFOT 8K CONTROL SYSTEM
on page 37.