Parameters
70
Operating manual INVEOR
34.011
Type of encoder
Unit: integer
min: 0
max.: 2
Parameter manual:
p. xy
Transfer status:
2
def.: 0
Own value (
to
be entered!
)
Relationship to
parameter:
34,010
34,012
34,013
Selection of the type of sensor
0 = inactive
1 = TTL sensor
2 = HTL sensor
WARNING
When selecting the HTL sensor, 24V is transmitted via the interface.
If using a TTL sensor, this could result in damage to the sensor.
34.012
Encoder line count
Unit: integer
min: 0
max.: 10000
Parameter manual:
p. xy
Transfer status:
2
def.: 1024
Own value (
to
be entered!
)
Relationship to
parameter:
34,010
34,011
34,013
Selection of the line count of the sensor used.
34.013
Encoder offset
Unit: °
min: 0
max.: 360
Parameter manual:
p. xy
Transfer status:
2
def.: 0
Own value (
to
be entered!
)
Relationship to
parameter:
34,010
34,011
34,012
An encoder offset for the sensor can be set here.
34.021
Flying restart
Unit:
min: 0
max.: 1
Parameter manual:
p. xy
Transfer status:
1
def.: 1
own value (
to
be entered!
)
Relationship to
parameter:
This parameter is used to activate the capture function.
0 = disable
1 = enable
Содержание INVEOR MA
Страница 1: ...Operating manual INVEOR Betriebsanleitung_INVEOR_A5 indd 1 28 02 11 10 33...
Страница 91: ...Guidelines Norms and Standards Operating manual INVEOR 91...
Страница 92: ...Guidelines Norms and Standards 92 Operating manual INVEOR...
Страница 93: ...Guidelines Norms and Standards Operating manual INVEOR 93...