Parameters
54
Operating manual INVEOR
3.052
PID derivative gain
Unit: s
min: 0
max.: 100
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
1,100
1,130
differential share of PID controller
3.060
PID feedback
Unit: integer
min: 0
max.: 3
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
1,100
1,130
3,061
Selection of the input source from which the feedback for the PID process
controller is imported:
0 = analogue input1
1 = analogue input2
3.061
PID inverted
Unit: integer
min: 0
max.: 1
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
3,060
The source of the feedback (parameter 3,060) is inverted
0 = disable
1 = enable
3.062 to 3.068
PID preset reference
Unit: %
min: 0
max.: 100
Parameter manual:
p. xy
Transfer status:
2
def.: 0
own value (
to
be entered!
)
Relationship to
parameter:
1,130
3,069
The PID preset reference depending on the switching patterns are to be
issued at the digital inputs 1 – 3 specified in parameter 3,069 (has to be
selected in parameter 1,130).
Содержание INVEOR MA
Страница 1: ...Operating manual INVEOR Betriebsanleitung_INVEOR_A5 indd 1 28 02 11 10 33...
Страница 91: ...Guidelines Norms and Standards Operating manual INVEOR 91...
Страница 92: ...Guidelines Norms and Standards 92 Operating manual INVEOR...
Страница 93: ...Guidelines Norms and Standards Operating manual INVEOR 93...