![Kostal INVEOR MA Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/kostal/inveor-ma/inveor-ma_operating-manual_1999368034.webp)
Installation
34
Operating manual INVEOR
5. Wire the motor cable to contacts U, V, W (and star point in some cases) in
the connection terminal, as described in the "Basic connection versions"
chapter. Use cable shoes (M5) to do this.
6. Before connecting an available motor PTC to the T1 and T2 terminals,
remove the preassembled short-circuit bridge (2).
The motor PTC is potential-free after connecting the INVEOR, therefore it
must be connected using a separate motor lead.
Replace the dummy screw with a suitable standard screw connection and
guide both ends to T1 and T2.
Fig. 14: Attaching the drive control
7. Position the drive control (1) on the adapter plate (2) so that the collar of
the adapter dips into the opening on the floor of the cooling element.
8. Fasten the control unit to the adapter plate with the help of the screws (3)
provided (torque: 4.0 Nm).
Содержание INVEOR MA
Страница 1: ...Operating manual INVEOR Betriebsanleitung_INVEOR_A5 indd 1 28 02 11 10 33...
Страница 91: ...Guidelines Norms and Standards Operating manual INVEOR 91...
Страница 92: ...Guidelines Norms and Standards 92 Operating manual INVEOR...
Страница 93: ...Guidelines Norms and Standards Operating manual INVEOR 93...