1
POWER switch ........................................ • Used to turn ON and OFF the power to the instrument. (Page 29)
2
Digital display section ............................. • Displays the measured values.
3
Analog display section ............................ • Displays the difference (%) between the measured value and the
target color or the difference (%) between measured values.
• The range for each dot can be set between 0.1 and 99%. (Page 68)
4
Measurement mode indications ............... • Displays the measurement mode in which the measured values
are displayed. (Page 40)
• The table below shows the relationship between measurement
modes and data displayed in the digital display section 2 and
analog display section 3.
Measurement mode
2
Digital display
3
Analog display
xyLv mode
x, y, Lv
∆
x,
∆
y,
∆
Lv
T
∆
uvLv mode
T,
∆
uv, Lv
∆
x,
∆
y,
∆
Lv
Analyzer mode (G reference)
R, B, G
R/G, B/G,
∆
G
Analyzer mode (R reference)
R, B, G
∆
R, B/G, G/R
u'v'Lv mode
u', v', Lv
∆
x,
∆
y,
∆
Lv
XYZ mode
XYZ
∆
x,
∆
y,
∆
Lv
5
LCD display ............................................ • Displays the memory channel, probe no., ID name, warning and
settings.
6
HOLD LED ............................................. • Lights up during hold.
7
REMOTE LED ........................................ • Lights up when the instrument is ready for communication with
the PC via RS-232C or USB interface.
8
Key panel ................................................. • Used to select/set probe no., SYNC mode, measurement speed,
analog display range and ID name, as well as entering values.
(Page 17)
9
Tilt stand
<Rear>
10
Probe connector [P1] ............................... • Used to connect a measuring probe. (Page 26)
11
USB connector ........................................ • USB interface for communication with the PC etc. (Page 86)
12
RS-232C connector ................................. • RS-232C compatible interface for communication with the PC
etc. (Page 84)
13
Vertical synchronizing signal .................. • Input the display’s vertical synchronizing signal into this terminal
input terminal
when performing measurement in EXT SYNC mode. (Page 28)
SYNC: Terminal shall tread as class 3 accordance with IEC
10101-1 Annex-H.
14
AC power connector ................................. • Connect the AC power cord to this connector to supply power to
the instrument. (Page 28)
• The rating is AC100-240V, 50-60 Hz, 50VA.
15
4-Probe Expansion Board slot ................. • Used to install the optional 4-Probe Expansion Board (CA-B04).
(Page 27)
Содержание CA-100PLUS
Страница 24: ...22...
Страница 46: ...44...
Страница 76: ...74...
Страница 100: ...98...
Страница 108: ...106 Dimension Diagram Main Body Measuring Probe 60 ISO 5mm screw depth 6mm...
Страница 123: ...121 Explanation Section...
Страница 124: ......
Страница 125: ...9222 1891 13 2002 KONICA MINOLTA SENSING INC AEIDPK 10 Printed in Japan...