5-99
5.3.6 FBS skew adjustment
When the image scanned with the document glass is skewed, you can adjust it by shifting a part.
1. Remove the Cover platen. (See “COVER PLATEN” on page 5-23.)
2. Remove the Cover top FBS. (See “CIS” on page 5-27.)
3. Remove one screw [1], lift up the Holder CIS [2] a little and remove the Guide bar [3].
* Make sure the Holder CIS [2] does not come off from the belt and remove the Guide bar [3].
>@
>@
>@
4. Cut the Guide bar [3] pin from the root using nippers or a cutter.